| Category |
Item |
Content |
| Fluoroscopy Capacity |
Perspective max rated capacity |
Tube current 8 mA ,Tube voltage 120kv |
| automatic fluoroscopy |
Tube voltage: 40kV~120kV ,adjust automatically
Tube current :0.3mA~4mA .adjust automatically |
| Manual Fluoroscopy |
Tube voltage 40 kv~110kv, continuous
Tube current :0.3mA~4mA continuous |
| pulse frequence |
Tube voltage 40kV~120kV, continuous
Tube current : 4.1mA~8mA continuous |
| X ray tube |
X ray tube special for High frequency |
Dual focus fixed anode x-ray tube: large focus:1.5, small focus: 0.3; High Frequency PowerSupply , Main inverter frequency :60KHZ, thermal capacity :35KJ(47Khu) Tube thermal capacity 460KJ(613KHU) |
| Video System |
Image intensifier |
Toshiba 9 "Image Intensifier (230mm) |
| Video camera |
Ultra-low-light digital camera for medical A / D digits? 12bit |
| Monitor |
Centre resolution greater than 1000 line, field frequency 75Hz |
| Central control |
High definition progressive scan output mode, multi-level noise reduction, multiple images stored; image vertical, horizontal image flip, positive and negative turn; LIH (last frame of the image to freeze) |
| Structure |
Column |
Vertical lifting range: ≥880mm focal screen distance: 1000mm |
| Examine table |
Lateral movement range: ≥180mm;
chassis 360deg electrical rotation |
| Performance |
Feature |
1. Using high-resolution image enhancement system, can reduce the dose, the doctor can clear room operation. |
| 2. With electric up and down movements, electric lateral movement, power rotation, to really realize people do not move while the machine move, safety and reliability. |
| 3. Ultimate resolution of the dynamic image 2.0LP/mm. Dynamic image without smearing. |
| 4. With the fluoroscopy KV / MA automatic tracking feature, the image brightness, sharpness automatically at its best. |
| 5. To achieve remote control of the operation, the maximum degree of protection from medical X-ray radiation effects, the patient doses significantly reduced. |
| 6. Hand brake and foot brake are two control modes, flexible switching, easy application. |
| 7. Programmable LCD with touch screen graphic, simple, elegant |
| 8. Electric iris limited beam, which can be electric rotary, electric opening and closing, electric O-ring. |
| 9. With the microphone to convenient doctor compartment operation. |
| Use |
This machine is suitable for human esophagus, chest and stomach, abdomen, limbs and other parts of the work of continuous fluoroscopy diagnosis. |