8.4-Inch 6-Parameter Patient Monitor (RPM-9000D)

  • Model: RPM-9000D
  • Units in Stock: 9

$812.50

Features:

Ergonomic design, portable, convenient for use
8.4" TFT display, configurable up to 8 waveforms, enables maximum data visibility for the most critical parameters
Unique digital SpO2 technology can work accurate during motion and low perfusion
Anti AC & high-frequency electrosurgical & defibrillator's interference
Rich screen layout, standard, large font, trend graph, OxyCRG, ECG full lead and others
Strong data storage: 720 hours trends, 10000 group NIBP, 1024 alarms events
ST analysis, arrhythmia analysis, pacemaker analysis, drug analysis and calculation
Audible & visual alarm available, adjustable
Patient information management function
Powerful software function to support use in NICU, ICU, OR, CCU or normal patient room
Flexible data storage & transfer/software upgrading based on USB
Wired/wireless networking with central monitoring system, up to 64 beds in one group
Built-in 3 trace thermal recorder for printing real-time and historical data
Multi-language I. E. English, Spanish, French, Italian, Turkish, German, Russian etc.
Super long life rechargeable dual lead-acid battery (optional) upto 4 hours of working time
Suitable for adult, pediatrics and neonate patients
Standard configuration:

ECG, NIBP, SpO2, TEMP, RESP, PR, Rechargeable lead-acid battery
Optional:

Dual TEMP
Dual IBP
EtCO2 (side stream)
CO (Cardiac Output)
Nellcor SpO2 module
Thermal recorder
Artema Multi-gas
Wall mount
Trolley
Rechargeable Lithium-Ion Battery
Specification:

ECG

Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ± 1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
ST section
Scope: ± 0.8mV
Precision: < ± 0.05mV

SpO2

Detection scope: 0%-100%
Accuracy ± 1% 90%-100%
± 2% 70%-89%

NIBP

Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: Dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg), 13.3kPa(100 mmHg), 16.0kPa(120 mmHg)
18.6kPa(140 mmHg), 20.0kPa(150 mmHg), 21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size: 1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
In -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static pressure: ± 3mmHg
Pulse rate: ± 2%

Resp

Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute ~100 minutes/minute
Precision of chest impedance method time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ± 1 time/minute

Temp

Single/double path
Type: Vascular/surface temperature
Scope: 20centigrade~50centigrade
Accuracy: ± 0.2centigrade

Invasive blood pressure (optional)

Single/double path
Type: Direct and continuous detection
Scope: -6.67kPa(-50mmHg)_46.67kPa(350mmHg)

Add to Cart: